Clean Room Indicator, 5" Display, Eth with Datalogging
Share this product with friends

Whatsapp

Telegram

Facebook

Twitter

Email

Messanger

Clean Room Indicator, 5" Display, Eth with Datalogging

Model : Hawkeye TFT501

  1. 4 Remote analog inputs with selectable Humidity, Temperature & Differential Pressure measurement
  2. 4 Digital input with user defined tags
  3. 1 Integral DP sensor
  4. 3 Analog outputs 4-20 mA/0-10 VDC with user selectable channel
  5. 4 Digital outputs with user defined tags
  6. 4 Relays with user selectable channels and user defined tags
  7. 5" TFT LCD with capacitive touch for user friendly navigation
  8. 21-days data stored with data interval 1-999 minutes
  9. Data is in CSV format and easy to use
  10. Ethernet port for retrieving of logged data using FTP protocol
  11. Software programmable ranges, units, input types, user defined inputs and user tags for all channels
  12. Power supply 17-30 VDC operated
  13. Alarm acknowledgment through touch
  14. Real time clock with battery back-up and Lo-Bat indication
  15. Calibration due date notification
  16. Help indication for user to change settings and access at ease
  17. Ethernet port for communication with PLC, SCADA
  18. Powerful, user-friendly, FDA21CFR Part11 compliant SCADA available
Read More...

Similar Products

product Clean Room Indicator, 5" Touchscreen Display
Clean Room Indicator, 5" Touchscreen Display |Hawkeye TFT511

  1. 4 Analog Inputs
  2. Integral DP Sensor
  3. 4 Digital Inputs, 3 Analog Outputs, 4 Relays
  4. Alarms with Buzzer and Alarm Acknowledge
  5. RS485/Modbus RTU
Read More...

product Clean Room Indicator, 7" Touchscreen Display
Clean Room Indicator, 7" Touchscreen Display |Hawkeye TFT711

  1. 3 Analog Inputs
  2. Integral DP Sensor
  3. 3 Digital Inputs, 3 Analog Outputs, 3 Relays
  4. Alarms with Buzzer and Alarm Acknowledge
  5. RS485/Modbus RTU
Read More...

product Clean Room Indicator, 7" Touchscreen Display, Ethernet with Datalogging
Clean Room Indicator, 7" Touchscreen Display, Ethernet with Datalogging |Hawkeye TFT701

  1. 3 Analog Inputs
  2. Integral DP Sensor
  3. 3 Digital Inputs, 3 Analog Outputs, 3 Relays
  4. Alarms with Buzzer and Alarm Acknowledge
  5. 21-day Datalogging, one CSV file per day
Read More...

product Clean Room Indicator, 5" Display
Clean Room Indicator, 5" Display |Hawkeye TFT521

  1. 4 Remote analog inputs with selectable Humidity, Temperature & Differential Pressure measurement
  2. 2 Digital input with user defined tags
  3. 1 Integral DP sensor
  4. 2 Relays with user selectable channels
  5. 5" TFT LCD with capacitive touch for user friendly navigation
  6. Software programmable ranges, units, input types, user defined inputs and user tags for all channels
  7. Power supply 17-30 VAC/DC operated
  8. Alarm acknowledgment through touch
  9. Real time clock with battery back-up
  10. Isolated ports for RS485/multidrop communication for PLC, SCADA etc.
  11. Powerful, user-friendly, FDA21CFR Part11 compliant SCADA available
Read More...

Customers Also Viewed

product 2-wire Temperature Transmitter, Isolated, Din-rail, Universal Input
2-wire Temperature Transmitter, Isolated, Din-rail, Universal Input |SCC602

  1. 2-wire technology, 4-20 mA analog output
  2. Universal Input includes thermocouples, RTDs, Linear Inputs
  3. High accuracy over total ambient temperature range
  4. An internal temperature sensor for active temperature compensation
  5. 4-20 mA input (optional)
  6. Wide supply voltage range
  7. User programmable measurement range settings
  8. Configuration with SB interface
  9. Simple and user friendly utility software
Read More...

product Single/Dual Channel PID Controller, Full-featured, 96Wx96Hx60D
Single/Dual Channel PID Controller, Full-featured, 96Wx96Hx60D |NEX205

  1. Single / Dual loop PID / Heat+Cool PID / 16-step profile control
  2. Universal input
  3. 5 relays, 2 isolated analog outputs, RS485/Modbus® RTU
  4. 6 digital inputs
  5. Field-selectable control device (relay/SSR/analog output)
Read More...

product Turbine Flowmeter With Flange & Sanitary Process Connection
Turbine Flowmeter With Flange & Sanitary Process Connection |TFM401

  1. Process connection as per ASME/EN/JIS/BS/DIN
  2. 3-line LCD display
  3. SS construction
  4. Unidirectional flow
  5. Multiple communication protocols
  6. Built-in diagnostics
Read More...

product Air Quality Monitor, PM1/PM2.5/PM4.0/PM10/CO2/CO/ TVOC/RH-T/AQI, 3 Relays, RS485 Modbus
Air Quality Monitor, PM1/PM2.5/PM4.0/PM10/CO2/CO/ TVOC/RH-T/AQI, 3 Relays, RS485 Modbus |AQM201

  1. Laser scatter method sensor for Particulate Matter measurement
  2. MEMS metal oxide semiconductor sensor to detect poor Air Quality
  3. NDIR CO2 sensor technology for superior stability in occupied and non-occupied buildings
  4. Measurement : Particulate Matter, TVOC, RH/T, CO2, CO, Air Quality Index
  5. Isolated RS485 Modbus® RTU output
  6. Dual relay output, 250 VAC-5A
  7. Field Replaceable PM, CO2, CO, TVOC, RH/T sensor
  8. RH/T sensor also provides the parameters like : Dewpoint, Absolute humidity, Heat index, Enthalpy, Air density
Read More...